Room Temperature Gyrotrons from 15 GHz to 35 GHz

Insight Product Company offers "Room Temperature" Gyrotrons and "Gyrotron Systems" within frequency range from 15 to 35 GHz and CW output power up to 10 kW.

"Room Temperature" gyrotrons works with room temperature electromagnets, and does not require liquid helium. Typical Gyrotron tube operates at 30 GHz and generate 10 kW CW continuously controlled from 0.3 to 10 kW.

How to order ?


GYROTRON TUBE:
Gyrotron tube is the key component of the "Gyrotron System" specially designed for high temperature processing of materials.
 
Frequency'  30 GHz
Maximum CW power  10 kW
High Voltage/current 10-26kV/2A
_____
'operating frequency is optional. Optional frequency is from 15 GHz to 35 GHz.
 

GYROTRON SYSTEM:
#1  GYROTRON TUBE Frequency'  30 GHz
. Maximum CW power 10 kW
. High Voltage/Current  10-26kV/2A
. Water cooled yes
#2  MAGNET SYSTEM main solenoid 130A*110V, oil-water (double circuit) cooled
. two small solenoids 10A*6V, air cooled
#3  MODE CONVERTER transmission, insulation and focusing line including three mirror quasi optical system transforming the gyrotron operating mode to the gaussian wave beam;
water-cooled calorimetric power meter;
microwave leakage proof case.
#4  SYSTEM OF OPTICAL ARC DETECTORS . .
#5  MICROWAVE FURNACE
vacuum proof, water-cooled cavity with 

 

inner diameter 50 cm, height 60 cm for operating within pressure range (10(-5) - 2) atm
. mode  stirrer; .
. diagnostic flange with leads-in for thermocouples .
. inlets for optical pyrometer and optical fibers; .
. 6 leads-in for an additional electric heating .
#6  MICROWAVE FURNACE VACUUM SYSTEM pump pumping rate 10 l/s and pressure down to 10(-5) atm
. liquid nitrogen trap .
. set of the electric valves .
. protection filters .
. vacuum measurement and system control devices .
#7  SAMPLE TEMPERATURE DIAGNOSTIC SYSTEM high temperature thermocouples .
#8  PC-BASED CONTROL SYSTEM multichannel registration of the processing parameters .
. manual/automatic processing control .
#9  GENERAL CONTROL AND SAFETY SYSTEM . .
#10 COOLING SYSTEM WITH SET OF CONTROL AND MONITOR DEVICES . .

______
' operating frequency is optional. Optional frequencies from 15 to 35 GHz
______
NOTE: components 3-10 of the GYROTRON SYSTEM, as well as the separate elements of these facilities are optional and can be modified and/or changed in accordance with customers request.
 



Requirements to Power Supplies:
 
High Voltage Power Supply DC voltage continuously regulated from -10 to -26 kV
. DC current 2 A

 
Main Solenoid Power Supply:  DC voltage 110 V Maximum
. DC current  up to 130 A
. Current instability < 2*10(-4)

_____
NOTE: Voltage and current rating are given for the gyrotron tube operated at 30 GHz.