Single Photon Detector System for Near-Infrared (1.3-1.6 um wavelength) waves with Closed-Cyle cooling |
Insight Product Company is proud to offer Single Photon Detector System for Near-Infrared (1.3-1.6 um wavelength) waves with Closed-Cylce (cryogen-free)cooling .
Insight Product Co. offers superconducting single photon detectors and ultra-low noise registration systems for the near infrared range.
All systems operate in continuous mode, no gating required.
The system is based on fiber-coupled NbN superconducting single photon detectors and can have several independent channels (up to 8).
The superconducting detectors require cryogenic temperature, and Insight offers two type of cooling systems (LHe and closed-cycle).
Advantages:
- Frequency range includes coverage into higher frequencies than other photon counters on the market.
- Short dead time (10 nanoseconds) compared to long dead time (microseconds) of alternatives. Therefore rapid repeition rate of 10s of MHz possible, whereas alternative have maximimum repetition rate of 1-10 kHz.
- Very small dark counts (10/second) compared to high dark count (1,000s / second) of alternatives. Does not require gated mode unlike alternatives. Works in continious operation mode.
Therefore device can detect CW signal, which is impossible for the alternatives.
Cryogen-free system (Closed-cycle)
The closed-cycle refrigerator is a cryogen-free cooling system that does not use liquid helium (operating temperature 2.5 degrees Kelvin).
This type of detection setup would be ideal when the investigator wants to avoid handling liquid helium.
The close-cycle refrigirator can operate uninterrupted for months from an electrical power source.
Spectral range |
Quantum efficiency (referred to optical input) |
1.3-1.6 um |
80% |
Parameters of the Cryogen-Free System
Element/Parameter |
Closed-cycle refrigerator |
Compressor |
Control Unit |
Weight, kg |
25 |
75 |
1 |
Length x width x height |
240 x 240 x 580 mm |
450 x 320 x 560 mm |
240 x 260 x 140 mm |
Preparation time |
150 minutes |
NA |
NA |
Maintenance, hours |
10,000 |
30,000 |
NA |
Power consumption |
1.5 kW * |
30 W * |
*Voltage of control unit and compressor: 100-240 V/ 50-60 Hz.
System specifications:
- Timing jitter: less than or equal to 50 ps
- Dark counts rate less than or equal to 10 cps
- Counting rate: more than or equal to 100 MHz (Dead time less than or equal to 10 ns)
- No afterpulsing
- Fiber coupling (no misalignment)
- Operation in continuous mode (no gating)
General parameters:
- Number of channels: 1-4
- Fiber: SMF 28e ( 980-HP, 780-HP, etc.)
- Original output voltage: ≤150 mV
- Possible types of output voltage: TTL, ECL, LVDS
- Electrical connection: SMA
- Driver interface: USB, LabVIEW
Applications:
- Photonic quantum computing
- Photon correlation measurements
- Quantum cryptography and QKD
- CMOS defect analysis
- Single α and β particles detection
- TCSPC
- Single molecule fluorescence spectroscopy
- Ballistic imaging
- Single plasmon detection, quantum plasmonics
- Free space communication
- LIDAR
- Time-resolved fluorescence measurements
- Single quantum dot fluorescence spectroscopy
- On-chip quantum optics
- Oxygen singlet/triplet fluorescence detection
- Flow cytometry
- Picosecond Integrated Circuits Analysis (PICA)
- Single electron detection
- Registration of extra low IR photon flux
- Optical coherence tomography
Contact:
E-mail: |
admin@insight-product.com |
Phone: |
(617) 965-8151 |
|