| Parameter |
Value |
| Operating frequency |
5712 +/- 4 MHz |
| Maximium pulse output power |
regime 1: at least 3.6 MegaWatt
regime 2: at least 3.6 MegaWatt
|
| Minimium pulse output power |
regime 1: at least 0.4 MegaWatt
regime 2: at least 0.4 MegaWatt |
| Power supply pulse power |
regime 1: does not exceed 7.7 MegaWatt
regime 2: does not exceed 7.7 MegaWatt
|
| Efficiency |
at least 45% |
| Heater power consumption |
does not exceed 480 Watt |
| Output Pulse duration |
2.0 - 8.0 microseconds |
| Duty cycle |
regime 1: at least 300
regime 2: at least 300 |
| Cathode Voltage |
regime 1: does not exceed 47 KilloVolt
regime 2: does not exceed 47 KilloVolt
|
| Heater voltage |
does not exceed 16.0 Volts |
| Control electrode voltage |
4.0 +/- 0.5 KilloVolts |
| Cathode pulse current |
regime 1: does not exceed 300 A
regime 2: does not exceed 300 A |
| Heater current |
does not exceed 30 A |
| Control electrode current |
does not exceed 150 microAmpere |
| Input pulse power |
does not exceed 30 Watt |
| Gain factor |
at least 50 dB |
| Voltage standing wave ratio (VSWR) |
does not exceed 1.25 |
| Dimensions of klystron |
25.2 inches (length) x 10.2 inches (width) |
| Mass of klystron, including magnets |
does not exceed 143.3 lbs |
| Coaxial input waveguide, dimensions |
0.79 inches x 1.57 inches |
| Output waveguide, dimensions |
0.79 inches x 1.57 inches |
| Cooling |
Water-based for collector and resonators |
| Water usage |
for collector: 26 Liters/Minute
for resonator: 8 Liters/Minute |
| Maximium pressure of air near output waveguide |
does not exceed 3 ATM |